OVERVIEW
FEATURES
PRESSURE RANGE
Pressure ranges to 60,000 psi (4,200 bar)
Precision accuracy to 0.01% RD
Pressure measurement accuracy of 0.02% FS
Fully temperature compensated accuracy
Precision sensor measurement accuracy to 0.01% RD
Gauge pressure measurement accuracy of 0.02% FS
Absolute Pressure measurement accuracy of 0.1% FS
Pressure ranges to 60,000 psi (4,200 bar)
Advanced temperature compensation
ISO 17025 accredited calibration and data included
[1]. Sealed gauge pressure for above 1000 psi
[2]. G=Gas, L=Liquid
Gauge Pressure
[1]
P/N
Pressure Range
Media
[2]
Accuracy(%FS)
Burst
Pressure
(psi) (bar)
V15 -15 -1.0 G 0.02
GP2 2 0.16 G 0.05
GP5 5 0.35 G 0.05
GP10 10 0.7 G 0.02
GP15 15 1.0 G 0.02
GP30 30 2.0 G 0.02
GP50 50 3.5 G , L 0.02
GP100 100 7.0 G , L 0.02
GP150 150 10 G , L 0.02
GP300 300 20 G , L 0.02
GP500 500 35 G , L 0.02
GP600 600 40 G , L 0.02
GP1K 1,000 70 G , L 0.02
GP2K 2,000 140 G , L 0.02
GP3K 3,000 200 G , L 0.02
GP5K 5,000 350 G , L 0.02
GP10K 10,000 700 G , L 0.02
GP15K 15,000 1,000 G , L 0.05 2x
GP20K 20,000 1,400 G , L 0.05 1.5x
GP25K 25,000 1,600 G , L 0.1 1.5x
GP30K 30,000 2,000 G , L 0.1 1.5x
GP36K 36,000 2,500 G , L 0.1 1.5x
GP40K 40,000 2,800 G , L 0.1 1.35x
GP50K 50,000 3,500 G , L 0.1 1.2x
GP60K 60,000 4,200 G , L 0.1 1.1x
Gauge pressure Differential pressure
With advanced microprocessor technology and state-of-the-art silicon pressure sensors, the Additel 160A series
Intelligent Digital Pressure Module (IDPM) provides an accurate, reliable, and economic solution for wide range
of pressure applications. It is loaded with functionality and remarkably easy to use. In order to reach the best
performance, every silicon pressure sensor in the module has been specially aged, tested and screened before
assembly. Designed as external pressure module for Additel 760 automatic handheld pressure calibrator, Additel 761
automated pressure calibrator and Additel 222A, Additel 223A and Additel 780 calibrators, the Additel 160A IDPM is
unmatched in performance and reliability.
Differential Pressure
P/N
Pressure Range
[1]
Media
Accuracy
(%FS)
Burst
Pressure
Static
Pressure
Range
(inH
2
0) (mbar)
DP1 ±1 ±2.5 G 0.05
[2]
100× ±10 psi
DP2 ±2 ±5.0 G 0.05
[2]
100× ±10 psi
DP5 ±5 ±10 G 0.05
[2]
50× ±10 psi
DP10 ±10 ±25 G 0.05
[2]
20× ±10 psi
DP20 ±20 ±50 G 0.05 20× ±10 psi
DP30 ±30 ±75 G 0.05 20× ±10 psi
DP50 ±50 ±160 G 0.05 ±10 psi
DP100 ±100 ±250 G 0.02 ±15 psi
DP150 ±150 ±350 G 0.02 50 psi
DP300 ±300 ±700 G 0.02 50 psi
[1] FS specification applies to the span of the range. Accuracy
includes 1 year stability.
[2] 0.05%FS accuracy (incl 6 months stability). One year accuracy
is 0.05%FS calibration accuracy combined with 0.05%FS one year
stability.
02
Corporate Headquarters
2900 Saturn St #B
Brea, CA 92821, USA
Salt Lake City Office
1364 West State Rd. Suite 101
Pleasant Grove, UT 84062, USA
Phone: 714-998-6899 Fax: 714-998-6999 Email: sales@additel.com
Pressure / Process Calibration Equipment
Rev # 20200525
SPECIFICATIONS
Compound Pressure
P/N
Pressure Range
Media Accuracy
Pressure Rating
psig bar.g Burst Over Pressure
CP2
±2 ±0.16 G 0.05% FS 3x 1.2x
CP5
±5 ±0.35 G 0.02% FS 3x 1.2x
CP10
±10 ±0.7 G 0.02% FS 3x 1.2x
CP15
±15 ±1.0 G 0.02% FS 3x 1.2x
CP30
-15 to 30 -1 to 2.0 G 0.02% FS 3x 1.2x
CP50
-15 to 50 -1 to 3.5 G 0.02% FS 3x 1.2x
CP100
-15 to 100 -1 to 7.0 G,L 0.02% FS 3x 1.2x
CP300
-15 to 300 -1 to 20 G,L 0.02% FS 3x 1.2x
CP500
-15 to 500 -1 to 35 G,L 0.02% FS 3x 1.2x
CP600
-15 to 600 -1 to 40 G,L 0.02% FS 3x 1.2x
CP1K
-15 to 1,000 -1 to 70 G,L 0.02% FS 3x 1.2x
CP2K
-15 to 2,000 -1 to 140 G,L 0.02% FS 3x 1.2x
CP3K
-15 to 3,000 -1 to 200 G,L 0.02% FS 3x 1.2x
CP5K
-15 to 5,000 -1 to 350 G,L 0.02% FS 3x 1.2x
CP10K
-15 to 10,000 -1 to 700 G,L 0.02% FS 2x 1.2x
Precision Sensors
[1]
- Absolute Pressure
P/N
Pressure Range
Media Accuracy
[2]
Pressure Rating
psia bar.a Burst Over Pressure
AP15R
0 to 15 0 to 1 G 0.01% FS 2x 1.2x
AP30R
0 to 30 0 to 2 G 0.01% rdg or 0.003% FS whichever is greater 2x 1.2x
AP50R
0 to 50 0 to 3.5 G 0.01% rdg or 0.003% FS whichever is greater 2x 1.2x
AP100R
0 to 115 0 to 8 G,L 0.01% rdg or 0.003% FS whichever is greater 2x 1.2x
AP300R
0 to 315 0 to 21 G,L 0.01% rdg or 0.003% FS whichever is greater 2x 1.2x
AP500R
0 to 515 0 to 36 G,L 0.01% rdg or 0.003% FS whichever is greater 2x 1.2x
AP1KR
0 to 1,015 0 to 71 G,L 0.01% rdg or 0.003% FS whichever is greater 2x 1.2x
AP2KQ
0 to 2,015 0 to 141 G 0.005% rdg + 0.005% FS 3x 1.1x
AP3KQ
0 to 3,015 0 to 201 G 0.005% rdg + 0.005% FS 3x 1.1x
AP6KQ
0 to 6,000 0 to 400 G,L 0.01% FS 3x 1.2x
AP10KQ
0 to 10,000 0 to 700 G,L 0.01% FS 2x 1.2x
AP15KQ
0 to 15,000 0 to 1,000 G,L 0.01% FS 2x 1.2x
AP20KQ
0 to 20,000 0 to 1,400 G,L 0.01% FS 2x 1.2x
AP30KQ
0 to 30,000 0 to 2,000 G,L 0.02% FS 1.5x 1.1x
AP40KQ
0 to 40,000 0 to 2,800 G,L 0.02% FS 1.5x 1.1x
[1] Contact Additel for other range options.
[2] Accuracy includes calibration uncertainty, linearity and long-term stability.
03
Corporate Headquarters
2900 Saturn St #B
Brea, CA 92821, USA
Salt Lake City Office
1364 West State Rd. Suite 101
Pleasant Grove, UT 84062, USA
Phone: 714-998-6899 Fax: 714-998-6999 Email: sales@additel.com
Pressure / Process Calibration Equipment
Rev # 20200525
Absolute Pressure
P/N
Pressure Range
Media Accuracy(%FS)
Burst
Pressure
(psi) (bar)
AP5 5 0.35 G 0.1
AP10 10 0.7 G 0.1
AP15 15 1.0 G 0.1
AP30 30 2.0 G 0.1
AP50 50 3.5 G 0.1
AP100 100 7.0 G , L 0.05 (0.1)
AP300 300 20 G , L 0.05 (0.1)
AP500 500 35 G , L 0.05 (0.1)
AP1K 1,000 70 G , L 0.05 (0.1)
AP3K 3,000 200 G , L 0.05 (0.1)
AP5K 5,000 350 G , L 0.05 (0.1)
ORDERING INFORMATION
Model Number
Model
Range type:
PSI - range by psi
BAR - range by bar
Pressure port type:
N - 1/4NPT male
N2 - 1/2NPT male
B - 1/4BSP male
B2 - 1/2BSP male
M - M20 X 1.5 male
ADT160A GP300 PSI N02
Pressure range P/N:
See pressure range table
Accuracy:
01 - 0.005% rdg+0.005%
of full scale
02 - 0.02% of full scale
05 - 0.05% of full scale
10 - 0.1% of full scale
01RD - 0.01%rdg
Accessories included
ISO 17025 accredited Calibration Certicate
Optional Accessories
Model
number
Description Picture
9060 Pressure module connection cable
SPECIFICATIONS
Standard Accuracy Precision Accuracy
CPXXX DPXXX GPXXX APXXQ APXXR
Operating temperature
-10°C to 50°C (14°F to 122°F) 15°C to 25°C (59°F to 77°F) 10°C to 30°C (50°F to 86°F)
Storage temperature
-20°C to 70°C (-4°F to 158°F) -20°C to 70°C (-4°F to 158°F)
Relative humidity
95% RH 90% RH
Pressure connections
(for external use only)
1/4NPT, 1/2NPT, 1/4BSP, 1/2BPS, M20x15 1/4NPT, 1/2NPT, 1/4BSP, 1/2BSP, M20x15
Enclosure
(for external use only)
SS enclosure SS enclosure
Dimensions (Dia x H)
33 mm x 123 mm (1.3” x 4.84”) Depends on the model 44 mm x 195 mm (1.7” x7.7”)
Weight
0.4 kg (0.99 lb) Depends on the model 0.7 kg (1.5 lb)
Warranty
1 Year 1 Year 1 Year
Barometric Pressure
P/N
Pressure Range
Media Accuracy
Burst
Pressure
Low High
BP 60 kPa 110 kPa G 40 Pa
Additel 223A with ADT160A Pressure Module