Series Automated Pressure Calibrators
Additel 761A
Automated and self-contained pressure generation
and control to 1,000 psi ( 70 bar)
Standard accuracy to 0.02%FS
Two removable internal pressure modules for multi-range selection
Control stability to 0.003%FS
Portable, designed for use in the field and in the lab
Ability to measure two external pressure modules
Wi-Fi, LAN, Bluetooth, USB and Ethernet communication
Full HART field communicator
HART and profibus communication
Data logging and task management
Patented electric pump technology and improved speed
OVERVIEW
At Additel, innovation and continuous improvement are part of our company's culture
and the products we introduce. When we set out to deliver the Additel 761A series
calibrators, we knew we needed to provide breakthrough improvements and additional
value to the existing line of calibrators (Additel 761 series). The ADT761A has many
improvements: increased pressure range to 1,000 psi (70 bar), removable internal
pressure modules, increased speed to pressure, ability to read two external pressure
modules, touch screen display, Wi-Fi, LAN, Bluetooth, and Ethernet communications,
double the original battery life, and more!
Just like the rst generation, this second generation product is completely self-contained
and automated with a built-in pump for pressure generation and precision control
technology. Simply set the desired pressure and watch the calibrator do the work.
02
Corporate Headquarters
2900 Saturn St #B
Brea, CA 92821, USA
Salt Lake City Office
1364 West State Rd. Suite 101
Pleasant Grove, UT 84062, USA
Pressure / Process Calibration Equipment
Phone: 714-998-6899 Email: sales@additel.com
Rev # 20230904
ADT761A-LLP
The Additel 761A-LLP is designed for low pressure calibration and comes
with a ±30 inH2O (±75 mbar) high range module and a low range module of
your choice ranging from ±20 inH2O to as low as ±0.25 inH2O (±50 to ±0.62
mbar). This unit has an accuracy of 0.05%FS with control stability better
than 0.005%FS. All measurements can be made in differential or gauge
pressures.
ADT761A-D
The Additel 761A-D also provides differential and gauge measurement
which covers the range of -13.5 to 35 psi (-0.95 to 2.5 bar). This unit comes
with a CP35 module (-13.5 to 35 psi) and one low range module of your
choice ranging as low as ±10 inH2O (25 mbar). Each ADT761A-D can
be preconfigured with the modules that fit your need to give you the best
precision at the pressures you perform calibrations.
ADT761A-1K
The Additel 761A-1K will generate and control from vacuum pressures up to
1,000 psig (70 bar.g). This unit can typically achieve 1,000 psi in less than 45
seconds. Like the ADT761A-500, both gauge and absolute pressures can be
realized due to a built-in barometer. Each unit comes with a CP1K module (-13
to 1,000 psig) for the high range and the low range can be preconfigured
based on the variety of modules available down to 30 psig (2 bar.g)
.
ADT761A-BP
The Additel 761A-BP is designed for calibration of barometer sensors. With
a range of 100 to 1200 hPa and an accuracy of 0.01%FS, this unit is ideal
for calibration on the bench or in the eld.
ADT761A-500
The Additel 761A-500 will generate and control from vacuum pressures up
to 500 psig (35 bar.g). Both gauge and absolute pressures can be realized
due to a built-in barometer. Each unit comes with a CP500 module (-13 to
500 psig) for the high range and the low range can be precongured based
on the variety of modules available down to 10 psig (0.7 bar.g).
Pressure / Process Calibration Equipment
03
Corporate Headquarters
2900 Saturn St #B
Brea, CA 92821, USA
Salt Lake City Office
1364 West State Rd. Suite 101
Pleasant Grove, UT 84062, USA
Phone: 714-998-6899 Email: sales@additel.com
Rev # 20230904
Electrical Specifications
Model
Specification
Range Resolution Accuracy Note
mA Measure
-25 to 25 mA 0.1 μA ±
(
0.008%RD + 1.0 μA
)
Impedance <10 Ω
-50 to 50 mA 0.1 μA ±
(
0.008%RD + 2.0 μA
)
V Measure -300 to 300 mV 1 μV ±
(
0.008%RD + 6 μV
)
Impedance <1 GΩ
V Measure
(Auto-ranging)
-5 to 5 V 20 μV ±
(
0.008%RD + 100 μV
)
Impedance >1 MΩ
-12 to 12 V 100 μV ±
(
0.008%RD + 320 μV
)
-30 to 30 V 100 μV ±
(
0.008%RD + 600 μV
)
Loop Power Source 24 V N/A ±1 V 50 mA (Max Loading)
mA Source
0 to 2.5 mA or
2.5 to 25 mA
0 - 2.5 mA: 0.05 μA
0 - 25 mA: 0.5 μA
0-2.5 mA: 0.008%RD + 0.2 μA
0-25 mA: 0.008%RD +1.0 μA
20 mA @ 1 KΩ
Power Source 16 to 30 V 1 V ±1 V 70 mA (Max Loading)
V Source 0 to 16 V 0.25 mV 0.008%RD + 500 μV
Pressure Switch
Mechanical Switch, Live
Mechanical Switch, NPN Switch,
PNP Switch
N/A N/A
Response time<10 ms.
If the switch is live, voltage
range will be (3-30) V
Temperature Compensation 18 °C to 28°C
Temperature Coefficient Outside of 18 °C to 28 °C: <± (0.0005%RD + 0.00005%FS) /°C
Misuse Protection Up to 30 V on any two sockets
Pressure Switch Test
HART / PROFIBUS PA
Model
Specification
761A-LLP 761A-D 761A-500 761A-1K 761A-BP
Max Pressure Range 30 inH2O (75 mbar) 35 psi (2.5 bar) 500 psig (35 bar.g) 1,000 psig (70 bar.g) 1,200 hPa
Min Pressure Range -30 inH2O (-75 mbar) -13.5 psi (-0.95 bar) -13 psi (-0.9 bar) -13 psi (-0.9 bar) 100 hPa
Accuracy
(
1)
0.05%FS 0.02%FS 0.02%FS
[2]
0.02%FS
[2]
0.01%FS
Stability 0.003%FS or 0.05 Pa 0.003%FS 0.003%FS 0.003%FS 0.02 hPa
Pressure Type Differential, Gauge Differential, Gauge Gauge, Absolute Gauge, Absolute Absolute
Over Range Indication 120%
Resolution 6 digits
Measurement Units
Pa, hPa, kPa, mPa, bar, mbar, psi, mmHg@0°C, cmHg@0°C, mHg@0°C, inHg@0°C, inH2O@4°C, mmH2O@4°C,
cmH2O@4°C, mH2O@4°C, mmH2O@20°C, cmH2O@20°C, mH2O@20°C, inH2O@20°C, inH2O@68°F, kgf/cm2, mtorr, torr,
lb/ft2, tsi, custom
Barometric Accuracy N/A N/A 55 Pa 55 Pa N/A
Pressure Specifications
[1] One year accuracy (including 1 year stability). FS specication applies to the span of the module range.
[2] Specication based on gauge measurement. An additional 55 pa uncertainty will need to be included when measuring in absolute mode.
Applicable only for use with the ADT761A-500 and ADT761A-1K.
* Additel 761A calibrators support 161 series intelligent digital pressure modules that are available for gauge, vacuum pressure from -15 psi to 60,000 psi
(-1 bar to 4,200 bar). For detailed specications refer to the 161 series pressure modules datasheet.
Supported
04
Corporate Headquarters
2900 Saturn St #B
Brea, CA 92821, USA
Salt Lake City Office
1364 West State Rd. Suite 101
Pleasant Grove, UT 84062, USA
Pressure / Process Calibration Equipment
Phone: 714-998-6899 Email: sales@additel.com
Rev # 20230904
Internal Module Specification and Compatibility
[1] FS specication applies to the span of the module range. Accuracy includes one-year stability, except for DP025 to DP10 modules.
[2] Accuracy is a 6 months spec, 1-year long-term drift is 0.2%FS.
[3] Accuracy is a 6 months spec, 1-year long-term drift is 0.1%FS.
[4] Accuracy is a 6 months spec, 1-year long-term drift is 0.05%FS.
[5] Specication based on gauge measurement. An additional 55 Pa uncertainty will need to be included when measuring in absolute mode.
[6] The low module pressure range may be outside the pressure range of the calibrator
.
Applicable only for use with the ADT761A-500 and ADT761A-1K.
*
ADT155 Pressure modules are calibrated in psi & inH2O.
Model
Range
inH2O
[6]
mbar
[6]
Media
Accuracy
(%FS)
[1]
Burst Pressure 761A-LLP 761A-D 761A-500 761A-1K
ADT155-20-DP025 ±0.25 ±0.62 G 0.2
[2]
100x
ADT155-10-DP050 ±0.5 ±1.25 G 0.1
[3]
100x
ADT155-05-DP1 ±1 ±2.5 G 0.05
[4]
100x
ADT155-05-DP2 ±2 ±5 G 0.05
[4]
100x
ADT155-05-DP5 ±5 ±10 G 0.05
[4]
50x
ADT155-05-DP10 ±10 ±25 G 0.05
[4]
20x
ADT155-05-DP20 ±20 ±50 G 0.05 20x
ADT155-05-DP30 ±30 ±75 G 0.05 20x
ADT155-05-DP50 ±50 ±125 G 0.05 3x
ADT155-02-DP100 ±100 ±250 G 0.02 3x
ADT155-02-DP150 ±150 ±350 G 0.02 3x
ADT155-02-DP300 ±300 ±700 G 0.02 3x
ADT155-02-DP400 -380 to 400 -950 to 1K G 0.02 3x
ADT155-02-DP800 -380 to 800 -950 to 2K G 0.02 3x
ADT155-02-DP1K -380 to 1K -950 to 2.5K G 0.02 3x
Gauge Pressure psig bar.g
ADT155-02-CP10 ±10 ±0.7 G
0.02
[5]
3x
ADT155-02-CP15 -13.5 to 15 -0.95 to 1 G
0.02
[5]
3x
ADT155-02-CP30 -13.5 to 30 -0.95 to 2 G
0.02
[5]
3x
ADT155-02-CP35 -13.5 to 35 -0.95 to 2.5 G
0.02
[5]
3x
ADT155-02-CP50 -13.5 to 50 -0.95 to 3.5 G
0.02
[5]
3x
ADT155-02-CP100 -13.5 to 100 -0.95 to 7 G
0.02
[5]
3x
ADT155-02-CP150 -13.5 to 150 -0.95 to 10 G
0.02
[5]
3x
ADT155-02-CP200 -13.5 to 200 -0.95 to 14 G
0.02
[5]
3x
ADT155-02-CP300 -13.5 to 300 -0.95 to 20 G
0.02
[5]
3x
ADT155-02-CP500 -13.5 to 500 -0.95 to 35 G
0.02
[5]
3x
ADT155-02-CP600 -13.5 to 600 -0.95 to 40 G
0.02
[5]
3x
ADT155-02-CP1K -13.5 to 1K -0.95 to 70 G
0.02
[5]
3x
Pressure / Process Calibration Equipment
05
Corporate Headquarters
2900 Saturn St #B
Brea, CA 92821, USA
Salt Lake City Office
1364 West State Rd. Suite 101
Pleasant Grove, UT 84062, USA
Phone: 714-998-6899 Email: sales@additel.com
Rev # 20230904
Pressure gauge / transmitter / switch calibration
General Specifications
Pressure Range
Type Model Pressure Range
High-Range Pressure Module Low-Range Pressure Module
Range Accuracy Range Accuracy
Low / Differential
Pressure
ADT761A-LLP-05-DPXX
-75 to 75 mbar
(-30 to 30 inH2O)
DP30: -75 to 75 mbar
(-30 to 30 inH2O)
0.05% FS
User selectable from
DP20 to DP025
See Internal Module
Table
ADT761A-D-02-DPXX-X
-0.95 to 2.5 bar
(-13.5 to 35 psi)
CP35: -0.95 to 2.5 bar
(-13.5 to 35 psi)
0.02% FS
User selectable from
DP10 to CP30
See Internal Module
Table
Standard Accuracy
Gauge / Absolute
Pressure
ADT761A-500-XX-CPXX-X
-0.9 to 35 bar
(-13 to 500 psi)
CP500: -0.9 to 35 bar
(-13 to 500 psi)
0.02%FS
User selectable from
CP10 to CP300
See Internal Module
Table
AADT761A-1K-XX-CPXX-X
-0.9 to 70 bar
(-13 to 1000 psi)
CP1K: -0.9 to 70 bar
(-13 to 1000 psi)
0.02%FS
User selectable from
CP30 to CP600
See Internal Module
Table
Barometric Pressure
ADT761A-BP-X
100 to 1200 hPa
(1.45 to 17.41 psi)
NA NA
100 to 1200 hPa
(1.45 to 17.41 psi)
0.01%
Task Menu
High Pressure Automated Calibration
Specification Description
User Interface Color touch screen and/or keypad operation
Channels
Four total: one electrical, high or low internal pressure
module, two external pressure modules
Enclosure IP Rating IP31
Battery
Rechargeable Li-Ion battery, typically 12 hours of
operation, recharges in less than 5 hours.
Power
Rechargeable Li-Ion battery, external power 110/220 V
power adapter 27 V
Display 7" TFT touch screen 800 x 480 color
Communications USB, LAN, Bluetooth, Wi-Fi and Ethernet
Weight <17.52 lb (7.95 KG)
Size 11.77 x 7.60 x 7.56 in (299 x 193 x 192 mm)
Certification
ISO 17025 accredited certificate of calibration with
NIST-traceable data
Data Storage
8 GB
Data Logging
Up to 1,000,000 readings (data and time stamped)
HART Communicator
Read, congure and calibrate HART devices - DD les
updated periodically
Task documentation
Up to 1000 tasks can be stored with data
Automation Functions Switch test, auto step, leak test
User Interface
Localization
English, German, French, Italian, Spanish, Portuguese,
Chinese, Japanese, and Russian
Pump life
>1,000,000 cycles
Environmental
Specifications
Operating temperature: 32°F to 122°F( 0°C to 50°C)
Compensated temperature: 32°F to 122°F( 0°C to 50°C)
Storage temperature: -20°C to 60°C ( -4°F to 120°F)
Humidity: <90%, non-condensing
Vibration and Shock
Vibration: 4 g (20 to 2,000 Hz)
Shock: 8 g, 1 meter drop test
Compliance CE
Software Compatibility
ACal, Additel Land and Additel Link for access via
mobile application
Warranty 1 year
Hose & Filter
End of Life
The estimated End of Life (EOL) expectancy for
all hoses and lters (pneumatic and hydraulic) is
approximately 10 years and should be replaced at the
rst sign of wear or damage.
06
Corporate Headquarters
2900 Saturn St #B
Brea, CA 92821, USA
Salt Lake City Office
1364 West State Rd. Suite 101
Pleasant Grove, UT 84062, USA
Pressure / Process Calibration Equipment
Phone: 714-998-6899 Email: sales@additel.com
Rev # 20230904
Accessories (included)
ADT106A-X
External Pressure Manifold
(Excl ADT761A-LLP)
1 pc
9818
110V/220V external
Power adapter
1 pc
9725
Chargeable Li-ion battery
1 pc
9240A
DP gauge holder witha built-in
80 ml chamber
(Only for ADT761A-LLP)
1 pc
9060
(Pressure module
connection cable)
1 pc
ADT100-761A-X
Hose Test Kit, 5 feet exible
hose
(excl ADT761A-LLP)
1 pc + 1 pc
adapter
1220211206
Adapter, quick female to barb
(Only for ADT761A-D)
1 pc
9022
Test Leads for calibrator
2 sets
(4 pcs)
9907
Carrying case for 761A
calibrator and accessory
1 pc
O-rings 20 pcs
Pressure Hose
1 pc for the
ADT761A-D
1 pc for the
ADT761A-BP
ISO17025 accredited
calibration certicate
1 pc
Threaded plug
(Excl ADT761A-LLP)
1 pc
USB Cable 1 pc
Barb Fitting
(Only for ADT761A-D
and ADT761A-BP)
1 pc
Silicone Tube
2 meters for
the ADT761A-
LLP
1 meter for the
ADT761A-D
Optional Accessories
ADT161
See datasheet of ADT161
for more info; connection
cable sold separately
9060
Pressure module
connection cable
9530
Additel / ACal Automated Calibration
Software
ADT100-761AHose
ADT761A hose, 5 feet
(polyamide, 2,390 psi burst)
ADT106A-X
External Pressure Manifold
(Excl ADT761A-LLP)
ADT100-761A-X Hose Test Kit, 5 feet exible hose
ORDERING INFORMATION
Pressure range:
See pressure range
table.
Pressure port type on External
Pressure Manifold:
N - 1/4NPT female
N2 - 1/2NPT female
B - 1/4BSP female
B2 - 1/2BSP female
M - M20X1.5 female
ADT761A
1K
Model Number
CP35
N
Module Range:
See internal module
table
02
Accuracy:
02 - 0.02% of full span
05 - 0.05% of full span