Video Demo

×

Video Demo

×

• Fully automatic calibrator with built-in pump and controller

• Switchable internal pressure modules for expandable ranges

• Accuracy (1 year) of 0.02%FS

• External pressure modules available (measure only)

• Less than 4 lbs (1.8 kg) for handheld operation

• Source pressure, measure pressure and electrical

• 4 channels

• Optional HART communications

• Optional data logging and task documenting

• USB and Wi-Fi communication

• ISO 17025-accredited calibration w/data included

A portable automated pressure calibrator in the palm of your hand—this could be our most exciting product yet! The Additel 760 series Automatic Handheld Pressure Calibrator takes portable pressure calibration to new levels. Weighing less than 4 lbs (1.8 kg), the ADT760’s innovative design contains a built-in pump, precision pressure sensor, internal controller and a large touch-screen color display. To generate pressure, simply key in the desired pressure and the Additel 760 will do the rest. Each unit has four channels: one internal pressure channel for source and measure pressures, two external pressure measurement channels, and one electronic measure and source channel. This series of calibrator has three standard models with the option of adding HART communications, documentation and data logging. 

ADT760-LLP
The 760-LLP is designed for low pressure calibration and comes with a built-in pressure module to ±30 inH2O (±75 mbar) and provides an accuracy to 0.05%FS (see ordering information for configurations with the option of the ADT760 and a module of your choice). Additional internal pressure modules (ADT155 series) are available and provide a variety of ranges down to ±0.25 inH2O (±0.62 mbar). The accuracy of 0.05%FS and control stability 0.005%FS is based on the internal module’s span. Measurements can be made in gauge or differential mode. 
 
Documenting Process Functionality 
Each model of the Additel 760 series has an option incorporating documentation and communication functions turning your 760 into a multifunction documenting process calibrator. This feature provides HART communication, task documentation and data logging.   

• Differential gauge calibration

• Low pressure calibration

• Differential transmitter calibration

• Differential switch calibration

• HART-smart transmitter calibration ( -DL version only )

• Pressure monitoring and data logging ( -DL version only )

760-2.jpg

Pressure Specification
Max Pressure Range ±30 inH2O (75 mbar)
Accuracy 0.05% FS
Stability <0.005% FS
Pressure Type Differential, Gauge
Over Range Indication 1.2
Resolution 6 digits
Measurement Units Pa, hPa, kPa, mPa, bar, mbar, msi, mmHg @ 0°C, cmHg @ 0°C, mHg @ 0°C, inHg @ 0°C, inH2O @ 4°C, mmH2O @ 4°C, cmH2O @ 4°C, mH2O @ 4°C, inH2O @ 20°C, mmH2O @ 20°C, cmH2O @ 20°C, mH2O @ 20°C, inH2O @ 68°C, kg/m2, mtorr, torr, lb/ft2, tsi, custom
Connection Barb fitting
Pressure Output Rate < 30 Seconds (30 inH2O/100 ml)
Selection Guide - Differential Pressure
ModuleModule Range[6]MediaAccuracy (%FS)[1]Burst Pressure760-LLP760-D760-MA
inH2Ombar
DP025±0.25±0.62G0.2[2]100x
DP050±0.5±1.25G0.1[3]100x
DP1±1±2.5G0.05[4]100x
DP2±2±5G0.05[4]100x
DP5±5±10G0.05[4]50x
DP10±10±25G0.05[4]20x
DP20±20±50G0.0520x
DP30±30±75G0.0520x
DP50±50±160G0.053x
DP100±100±250G0.023x
DP150±150±350G0.023x
DP300±300±700G0.023x
DP400-380 to 400-950 to 1KG0.023x
DP800-380 to 800-950 to 2KG0.023x
DP1K-380 to 1K-950 to 2.5KG0.023x
[1] FS specification applies to the span of the module range. Accuracy includes one-year stability, except for DP025 to DP10 modules.
[2] Accuracy is a 6 months spec, 1-year long-term drift is 0.2%FS.
[3] Accuracy is a 6 months spec, 1-year long-term drift is 0.1%FS
[4] Accuracy is a 6 months spec, 1-year long-term drift is 0.05%FS.
[5] Specification based on gauge measurement. An additional 60 pa uncertainty will need to be included when measuring in absolute mode. Applicable only for use with the ADT760-MA
[6] The low module pressure range may be outside the pressure range of the calibrator
* ADT155 Pressure Modules are calibrated in psi and inH2O.
Selection Guide - Gauge Pressure
ModuleModule Range[6]MediaAccuracy (%FS)[1]Burst Pressure760-LLP760-D760-MA
psi bar
CP10±10±0.7G0.02[5]3x
CP15-13.5 to 15-0.95 to 1G0.02[5]3x
CP30-13.5 to 30-0.95 to 2G0.02[5]3x
CP35-13.5 to 35-0.95 to 2.5G0.02[5]3x
CP50-13.5 to 50-0.95 to 3.5G0.02[5]3x
CP100-13.5 to 100-0.95 to 7G0.02[5]3x
CP150-13.5 to 150-0.95 to 10G0.02[5]3x
CP200-13.5 to 200-0.95 to 14G0.02[5]3x
CP300-13.5 to 300-0.95 to 20G0.02[5]3x
[1] FS specification applies to the span of the module range. Accuracy includes one-year stability, except for DP025 to DP10 modules.
[2] Accuracy is a 6 months spec, 1-year long-term drift is 0.2%FS.
[3] Accuracy is a 6 months spec, 1-year long-term drift is 0.1%FS
[4] Accuracy is a 6 months spec, 1-year long-term drift is 0.05%FS.
[5] Specification based on gauge measurement. An additional 60 pa uncertainty will need to be included when measuring in absolute mode. Applicable only for use with the ADT760-MA
[6] The low module pressure range may be outside the pressure range of the calibrator
* ADT155 Pressure Modules are calibrated in psi and inH2O.
Electrical Specification

Range Resolution Accuracy Note
mA Measure ±30 mA 0.0001 mA 0.01%RD+0.005%FS Impedance<10Ω
V Measure ±30 V 0.0001 V 0.01%RD+0.005%FS Impedance >1MΩ
mA Source 24 mA 0.001 mA 0.01%RD+0.005%FS 20 mA @ 1K
Loop Power Source 24 V N/A ±1 V 50 mA (Max Loading)
Pressure Switch Open, close. Support for mechanical switches and NPN/PNP digital switches.
Temperature Compensation 41°F to 95°F (5°C to 35°C)
Temperature Coefficient < ± ( 0.001%RD + 0.001%FS ) / °C outside of 5°C to 35°C
General Specifications
Specification Description
Channels Four total: one electrical, one internal pressure, two external pressure (measure only)
Enclosure IP Rating IP52 water and dust proof
Battery Rechargeable Li-Ion battery, typically 10 hours of operation, recharges in less than 4 hours
Display Color 800 x 480 TFT 5-inch touch screen
Communications USB, WiFi
Weight <4 lbs (<1.8 kg)
Size 9.3 x 4.3 x 2.8 in (235 x 110 x 70 mm)
Certification ISO17025 accredited certificate with data included
HART Communications Optional (ADT760-X-DL model)
Data Logging Optional (ADT760-X-DL model), up to 1,000,000 readings (date and time stamped)
Task Documentation Optional (ADT760-X-DL model) up to 1000 tasks
Automation Functions Switch test, auto step, leak test
Misuse Protection Up to 30 V on any two sockets
Multi Lingual Interface English, German, French, Italian, Spanish, Portuguese, Chinese, Japanese, and Russian
Pump Life >500,000 cycles
Power Rechargeable Li-Ion battery, external power: 110/220 V power adapter 10 V
Environment Specifications Operation: 32°F to 122°F (0°C to 50°C), 0-90% RH, less than 3,000 meters Compensated temperature: 32°F to 122°F (0°C to 50°C) Storage temperature: -4°F to 158°F (-20°C to 70°C)
Vibration and Shock Vibration: 4g (20 to 2,000 Hz) Shock: 8g, 1 meter drop test
Compliance CE
Software ACal, PCal, Land, LogII
Warranty 1 year

Documents:

File nameUpload DateSize
Additel 760 Automatic Handheld Pressure Calibrator User Manual 2019.3.11 3.1 MB
Additel 760 Automatic Handheld Pressure Calibrator Datasheet 2018.3.27 4.5 MB
Additel 760 Series Firmware Update Information 2019.4.15 0.2 MB
Additel 760 Selection Guide 2019.5.21 0.7 MB
Additel 760 Battery MSDS 2020.6.11 2.6 MB

Update Packages:

File name Upload Date Size
Additel 760 Firmware Update Package 6.1 MB

760OI LLP.JPG760LLP OIPM.JPG760 standard accessories.JPG
760 optional accessories.JPG