{"hyperlinks":[{"name":"Additel 773/783/793 Firmware Update Tool","primary_url":"/download/firmware/ADT773_and_783_and_793/MPC_Update.zip","versions":[{"version_number":"2.0.4.5","date":"2026-07-06","size":"96 MB","description":"1. Fixed known issues.","url":"/download/firmware/ADT773_and_783_and_793/MPC_Update.zip"},{"version_number":"2.0.3.6","date":"2025-10-27","size":"94 MB","description":"Changes in the main program:\n[New] Added support for command configuration for special models;\n[New] Added main range switching for modules;\n[New] Added fine pressure adjustment function;\n[New] Added Modbus command protocol;\n[New] Added support for Link App function;\n[New] Added BP model;\n[New] Added one-click log export;\n[Fixed] Fixed calibration issue for the electrical measurement module;\n[Fixed] Fixed issue of the pressure control unit going offline;\n[Fixed] Fixed range mismatch issue for the pressure switch;\n[Fixed] Corrected Pace6000 compatibility commands;\n[Fixed] Fixed intermittent delays in serial port command response;\n[Fixed] Fixed issue where continuous trigger clicks caused the touchscreen to freeze;\n[Fixed] Fixed related bugs;\n[Optimized] Optimized accumulator pressure testing procedure.\n\nChanges in control board program:\nLiquid model:\n[Fixed] Optimized the capacitive grating ruler test and pump test procedures;\n[Fixed] Fixed an issue during the start of pressure amplification where the amplification state is changed immediately to prevent anomalies caused by setpoint changes while waiting for the amplifier to shut down;\n[Fixed] Added default calibration values for PIN and PCTL sensors;\n[Fixed] Fixed a bug where forwarded commands could be lost.\n\nAir Models:\n[Fixed] Optimized pressure control speed and overshoot under high vacuum conditions;\n[Fixed] Fixed an issue where the LP air pump's positive pressure capability would decrease after a period of use. The positive pressure capability has been reduced from 150kPa to 140kPa, and the corresponding positive pressure target range has been adjusted accordingly;\n[Fixed] Fixed a bug where the fan in the pressure control unit did not run for LP and 700kPa built-in pump models;\n[Fixed] Fixed a bug where forwarded commands from the pressure module could be lost;\n[Fixed] Fixed the evacuation process for unlimited speed: when pressure is above 7000kPa, it is first controlled to 7000kPa before being directly evacuated;\n[Fixed] Optimized command function to support zeroing for multiple absolute pressure modules in gauge pressure mode;\n[Fixed] Fixed a bug where manual switching to the low-pressure module was not possible when absolute and gauge pressure modules were mixed."},{"version_number":"2.0.2.1","date":"2025-04-07","size":"85 MB","description":"1. Add status setting after Auto step is completed.\n2. Optimized the pressure ranges of ADT793.\n3. Better support load volume expander.\n4. Fixed some bugs."},{"version_number":"2.0.1.15","date":"2025-01-20","size":"85 MB","description":"1. Added support for the ADT783-6k.\n2. Added support for noise-reducing valves.\n3. Fixed some bugs.\n4. Optimized the performance of the solenoid valves."},{"version_number":"2.0.1.11","date":"2024-12-03","size":"85 MB","description":"1. Added support for the CC30 module.\n2. Added an icon for Passive Control and Fixed Volume to the main display.\n3. Added Spanish as a language.\n4. Fixed some bugs."},{"version_number":"2.0.0.37","date":"2024-04-29","size":"79 MB","description":"1. Optimized system volume.\n2. Optimized some communication configuration.\n3. Updated the control board."},{"version_number":"2.0.0.35","date":"2024-04-23","size":"77 MB","description":"1. Optimized the auto zero function for the ADT773 and ADT783, supporting zeroing both the high and low range.\n2. Optimized performance of the ADT773.\n3. Optimized control settings at the set point values between 1 kPa and 24 kPa.\n4. Optimized the user interface in applications.\n5. Optimized boot process.\n6. Fixed an Auto-Tune failure bug that was related to having the wrong differential pressure calculations for AP modules.\n7. Fixed an Auto-Tune bug where the vacuum source was connected to atmosphere through OUT and VENT during the initial stage of Auto-Tune.\n4. Fixed some other bugs."},{"version_number":"2.0.0.23","date":"2023-11-20","size":"74 MB","description":"1. Fixed some UI bugs."}],"selected_version":0},{"name":"Additel 9054 Module Adjustment Software","primary_url":"/downloads/Fit/Additel_Fit.zip","versions":[{"version_number":"1.0.18.02","date":"2026-03-19","size":"4 MB","url":"/downloads/Fit/Additel_Fit.zip"},{"version_number":"1.0.15","date":"2024-01-22","size":"3 MB","description":"Introducing the Additel 9054 Module Adjustment Software (Additel Fit)."}],"selected_version":0},{"name":"USB Driver","primary_url":"/download/drivers/Additel USB Driver.zip","versions":[{"version_number":"1.0.0.1","date":"2024-10-29","size":"5 MB","description":"Supports Windows 7 a bit better.","url":"/download/drivers/Additel USB Driver.zip"},{"version_number":"1.0.0.0","date":"2024-07-17","size":"5 MB"}],"selected_version":0},{"name":"Additel 7X3 LabVIEW Driver (Single channel)","primary_url":"https://www.additel.com/download/drivers/Additel_7X3_LabVIEW_Driver.zip","versions":[],"selected_version":0}],"title":"Software and Firmware"}