• Sourcing, simulating and measuring pressure, temperature and electrical signals
• Built-in Barometer
• Intrinsically safe models available (Ex)
• Large Smartphone like touchscreen user experience
• USB Type-C and Bluetooth communications
• IP67 Rated
• High Voltage Measurement Capability (±300V AC)
• True RMS Voltage Meter Capability
• Dual channel pressure module ports
• High Static Differential Pressure Measurement 0.002% FS
• ISO 17025-accredited calibration w/data included
Additel’s new Multi-functional Process Calibrator series takes portability, functionality, and accuracy to a whole new level and packages it with an intuitive and easy to use color touchscreen display. The ADT226 is a powerful yet cost effective process calibrator, which has an ATEX certified intrinsically safe option - ADT226Ex allowing you to perform calibration work in the harshest of environments. We’re confident these new tools will not only meet your calibration requirements but will make metrology simple for you!
Description | Picture of the 226 in Action / Screenshot of one of the 226’s Applications |
---|---|
Easy-to-use Cellphone Like Interface |
|
The ADT226 series brings an all new user interface to the world of process calibrators. With a menu driven interface and small size/weight, the ADT226 is the industry's smallest multifunctional process calibrator with an intrinsically safe version to boot (ADT226Ex). It adopts advanced human hand engineering design for the most convenient field handheld process calibrator available. The ADT226 has been developed with a powerful embedded operating system which solves common problems of other designs including slow response, cumbersome key operation, high power consumption and overall slow processing. | |
Accuracy |
|
Additel's new and improved ADT226 series provides much improved accuracies including an electrical accuracy of 0.015% RD + 0.005% FS, high-static differential pressure mode accuracy to 0.002% FS and across the board improvements in temperature measurement accuracies. | |
Thermocouple Measurement Performance |
|
The ADT226 series delivers highly improved thermocouple measurement capabilities by vastly improving the cold junction compensation(CJC) specifications and a much improved stabilization time. | |
Time Saving Features |
|
In addition to all the great features mentioned above, the ADT226 series is loaded with time saving features like our builtin pressure and temperature converter, thermal calculator, wiring diagram guide for assisting with electrical connections, a built-in diagnostic center including intelligent alarm messaging and a real time error report and comprehensive selftesting to help our customers get the very most out of their investment in Additel calibration tools. | |
Portable and Robust |
|
The demands of remote calibration work can be challenging. The ADT226 series is lightweight and highly portable and utilizes an advanced color LCD screen to help ensure you can easily see, even in the (Ex) intrinsically safe versions. All models in the ADT226 family have been designed with ruggedness and dependability in mind and meet IP67 standards with a 1-meter drop test, 4G vibration, xenon exposure and 130g steel ball drop testing of the display. Other environmental conditions have also been considered, such as temperature and humidity. To combat these external elements, Additel has designed a unique internal circuit design and process technology to allow for the utmost confidence in your critical calibration and measurement work. | |
Intrinsically Safe Option |
|
The Additel 226Ex series calibrators have passed the most stringent testing by certified organizations to acquire intrinsically safe certificates, ATEX, IECEX. The explosion-proof grade (Ex ia IIC T4 Ga), can be widely used in potentially explosive environments, such as oil and gas platforms, oil refineries, chemical and petrochemical plants, pharmaceutical industries, energy and gas processing industries. Each intrinsically safe calibrator has an advanced transflective color LCD display which has enhanced visibility when viewed in direct sunlight. No matter where youer work takes you, these calibrators are up to the task. | |
Voltage Meter (RMS) |
|
The Additel 226 non-Ex version is equipped with “true effective value” RMS measuring function, which can measure the RMS of various waveforms with no need to consider distortion or waveform parameters and other errors caused by various waveforms. | |
Targeted Application Features |
|
The onboard applications provide a useful selection of features including high static differential pressure mode, pressure leak test, safety valve test, analog transmitter calibration, unit converter, thermal calculator, and snapshots to name a few. High static differential pressure mode uses two sensors, unique calculation technology to achieve a differential pressure measurement to 0.002% FS at high static pressures. The leak test will automatically calculate the pressure drop to determine a leak condition. The safety valve test is a specialized task which captures the exact pressure release point by taking 10 readings per second during a valve crack test. You will find this and much more as we continue to develop new apps at Additel. | |
Connectivity and Battery |
|
Users can remotely connect mobile devices to the ADT226 via Bluetooth with an unobstructed distance up 20 meters. The included USB type-C comm port and cable provide a hard wired communication option as well as charging for the removeable Li-ion battery, which provides up to 35 hours of run time. |
Electrical Specifications - Source Accuracy | ||||||
---|---|---|---|---|---|---|
Specifications | ADT226 | ADT226Ex | ||||
Range | Resolution | Accuracy | Range | Resolution | Accuracy | |
Voltage DC | -150 to 150 mV [1] | 5 uV | 0.015%RDG + 15 uV | 0 to 10.5 V | 0.2 mV | 0.02%RDG + 0.5 mV |
-1.5 to 1.5 V [1] | 0.05 mV | 0.015%RDG + 0.15 mV | ||||
-15 to 15 V [1] | 0.5 mV | 0.015%RDG + 1.5 mV | ||||
Current DC | 0 to 25 mA | 0.5 uA | 0.015%RDG + 1.2 uA | 0 to 25 mA | 0.5 uA | 0.02%RDG + 1.25 uA |
Resistance | 0 to 400 Ω | 10 mΩ | 0.015%RDG + 20 mΩ | 0 to 400 Ω | 10 mΩ | 0.015%RDG + 20 mΩ |
0 to 4000 Ω | 100 mΩ | 0.015%RDG + 200 mΩ | 0 to 4000 Ω | 100 mΩ | 0.015%RDG + 200 mΩ | |
Frequency | (0.01 ~ 5) Hz | 0.00001 Hz | 0.005%RDG + 0.00005 Hz | (0.01 ~ 5) Hz | 0.00001 Hz | 0.005%RDG + 0.00005 Hz |
(5 ~ 50) Hz | 0.0001 Hz | 0.005%RDG + 0.0005 Hz | (5 ~ 50) Hz | 0.0001 Hz | 0.005%RDG + 0.0005 Hz | |
(50 ~ 500) Hz | 0.001 Hz | 0.005%RDG + 0.005 Hz | (50 ~ 500) Hz | 0.001 Hz | 0.005% RDG + 0.005 Hz | |
(500 ~ 5000 Hz) | 0.01 Hz | 0.005%RDG + 0.05 | (500 ~ 5000) Hz | 0.01 Hz | 0.005% RDG + 0.05 Hz | |
(5000 ~ 50000 Hz) | 0.1 Hz | 0.005%RDG + 0.5 Hz | (5000 ~ 50000) Hz | 0.1 Hz | 0.005%RDG + 0.5 Hz | |
Frequency (Sine wave & regular wave) [1] | (0.1 ~ 50) Hz | 0.001 Hz | 0.004 Hz | N/A | ||
(50 ~ 500) Hz | 0.01 Hz | 0.04 Hz | ||||
(500 ~ 5000) Hz | 0.1 Hz | 0.4 Hz | ||||
(5000 ~ 50000) Hz | 1 Hz | 4 Hz | ||||
Voltage mV (TC) | -10 to 75 mV | 1.5 uV | 0.015%RDG + 4.0 uV | -10 to 75 mV | 1.5 uV | 0.02%RDG + 4.0 uV |
Pulse | 0 to 9999999 | 1 | N/A | 0 to 9999999 | 1 | N/A |
Optional rising edge and falling edge, minimum threshold voltage: 2.5V | ||||||
Loop power (max 25mA) | 24 V | N/A | ±1 V | 22 V | N/A | ± 10% |
For more information about temperature coefficients or other device outputs, see datasheet notes. | ||||||
[1] Available per request |
Electrical Specifications - Measurement Accuracy | ||||||
---|---|---|---|---|---|---|
Specifications | ADT226 | ADT226Ex | ||||
Range | Resolution | Accuracy | Range | Resolution | Accuracy | |
Voltage DC | -300 to 300 mV | 1 μV | 0.015% RDG + 15 uV | -300 to 300 mV | 1 μV | 0.02% RDG + 15 uV |
-30 to 30 V | 0.1 mV | 0.015%RDG + 1.5 mV | -30 to 30 V | 0.1 mV | 0.02% RDG + 1.5 mV | |
Impedance: -300 mV to 300 mV = > 100 MΩ, -30 V to 30 V = >1 MΩ | ||||||
DC High Voltage | -300 to 300 V | 10 mV | 0.05% RDG + 30 mV | N/A | ||
The highest input voltage is 300 V, IEC61010 300V CATII | ||||||
Common mode rejection: >100 dB (at 50 or 60 Hz) | ||||||
Impedance: > 4 MΩ, DC coupling | ||||||
AC High Voltage | 300V (40 to 500 Hz) | 10 mV | 0.5% RDG + 150 mV | N/A | ||
The highest input voltage is 300 V, IEC61010 300V CATII | ||||||
9% to 100% of range is suitable for the above accuracy indicators | ||||||
Impedance: >4 MΩ, <100pF, AC coupling | ||||||
Current DC | -30 to 30 mA | 0.1 μA | 0.015% RDG + 1.5 uA | -30 to 30 mA | 0.1 μA | 0.02% RDG + 1.5 uA |
Resistance (4-Wire) | 0 to 400 Ω | 1 mΩ | 0.015% RDG + 20 mΩ | 0 to 400 Ω | 1 mΩ | 0.02% RDG + 20 mΩ |
0 to 4000 Ω | 10 mΩ | 0.015% RDG + 200 mΩ | 0 to 4000 Ω | 10 mΩ | 0.02% RDG + 200 mΩ | |
2-Wire + 50 mΩ, 3-wire+ 10 mΩ | ||||||
Excitation current: 0.2 mA | ||||||
Voltage mV (TC) | -10 to 75 mV | 0.1 μV | 0.015% RDG + 4.0 μV | -10 to 75 mV | 0.1 μV | 0.02% RDG + 4.0 μV |
Impedance: >100 MΩ | ||||||
Frequency | (0.01 ~ 5) Hz | 0.00001 Hz | 0.005%RDG + 0.00005 Hz | (0.01 ~ 5) Hz | 0.00001 Hz | 0.005%RDG + 0.00005 Hz |
(5 ~ 50) Hz | 0.0001 Hz | 0.005%RDG + 0.0005 Hz | (5 ~ 50) Hz | 0.0001 Hz | 0.005%RDG + 0.0005 Hz | |
(50 ~ 500) Hz | 0.001 Hz | 0.005%RDG + 0.005 Hz | (50 ~ 500) Hz | 0.001 Hz | 0.005%RDG + 0.005 Hz | |
(500 ~ 5000) Hz | 0.01 Hz | 0.005%RDG + 0.05 Hz | (500 ~ 5000) Hz | 0.01 Hz | 0.005%RDG + 0.05 Hz | |
(5000 ~ 50000) Hz | 0.1 Hz | 0.005%RDG + 0.5 Hz | (5000 ~ 50000) Hz | 0.1 Hz | 0.005%RDG + 0.5 Hz | |
Minimum threshold voltage: 2.5 V | ||||||
Supported units: Hz, kHz, MHz, CPM, CPH, s, ms, µs | ||||||
Duty Cycle | (1%~99%) @ ≤ 10000 Hz | 0.01% | 0.1% kHz + 0.05% | N/A | ||
(5%~99%) @ ≤ 50000 Hz | 0.1% | |||||
Pulse | 0 to 9999999 | 1 | N/A | 0 to 9999999 | 1 | N/A |
Optional rising edge and falling edge, minimum threshold voltage: 2.5V | ||||||
Switch | Support for dry or wet switch, voltage range of 3 to 30 V, response speed of < 10 ms | |||||
Note 1: When the environment temperature is (-10 ~ +10)°C and (30 ~ 50)°C, the temperature coefficient is: Voltage, current, thermocouple, thermal resistance output: ± 5 ppm FS/°C (for Non-Ex version); When the enviornment temperature is (-20 ~ -10)°C, the temperature coefficient is: Voltage, current, thermocouple thermal resistance output: ± 5 ppm FS/°C (for Ex version); AC High Voltage TRMS measurement: ± (250 ppmRDG + 25 ppmFS)/°C; DC high Voltage measurement: ± 25 ppm FS/°C. | ||||||
Note 2: Output features: Voltage range: (-300 ~ 300) mV, input impedance > 100 MΩ; (-30 ~ 30) V, input imedance > 1 MΩ; Current measurement: input impedance < 40 Ω; TC measurement input impedance > 100 MΩ; AC High Voltage TRMS measurement: input imedance: > 4MΩ, <100pF, AC coupling; Maximum input voltage: 300 V, IEC61010 300V CATII; 9% ~ 100% of the range is applicable to the accuracy index above. DC High Voltage measurement: >4 MΩ, DC coupling: Maximum input voltage: 300 V, IEC61010 300V CATII; Common-mode rejection: > 100db (in 50 or 60 Hz) | ||||||
Note 3: The thermal resistance measurement excitation power supply is 0.2 mA. There are four wire system, three wire system and two wire system measurement modes at each gear position. The accuracy indicators are as follows; The accuracy data given in the table is the accuracy data in 4-line system,; 3-wrie ssytem acuracy is +10 mΩ on the basis of 4-wire system accuracy; 2-wire accuracy is +50 mΩ on the basis of 4-wire accuracy; | ||||||
Note 4: Minimum threshold voltage for the frequency and pulse measurement: 2.5V; | ||||||
Note 5: Frequency measurment unit: Hz, kHz, MHz, CPM CPH, s, ms, us; | ||||||
Note 6: Optional rising edge or descending edge trigger mode for pulse measurement. |
General Specification | ||
---|---|---|
ADT226 | ADT226Ex | |
Operating Temperature | -10°C to 50°C | -20°C to 50°C |
Specification guaranteed temperature range | 10°C to 30°C | -10°C to 50°C |
Storage Temperature | -30°C to 70°C | |
Humidity | <95%, non-condensing | |
Power supply | 6600mAh, 23.8Wh lithium battery, charging time 4~6 hours, battery pack can be charged independently | 4000mAh 14.4Wh Explosion-proof lithium battery packcharging time 6~8 hours, battery pack can be charged independently |
User interface | Icon drive menus | Icon driven menus with navigation buttons |
Ports protection voltage | 50V max | 30V max |
Display | 5.0 inch 480 x 800 mm TFT LCD capacitive screen | 4.4 inch 640 x 480 mm color display capacitive screen |
Maximum altitude | 3000 meters | |
European Compliance | CE Mark | |
Electrical Connection | Ø4mm sockets and flat mini-jack thermocouple socket | |
Size | 6.97" x 4.13" x 2.04" (177 mm x 105 mm x 52 mm) | |
Weight | 1.6 lb (0.7 kg) | 1.65 lb (0.75 kg) |
Battery | Rechargeable Li-ion battery (included) | |
Battery Life | Typically 12 hours | Typically 35 hours |
Battery Charge | 110V/220V external power adapter included. Battery can be charged external to the unit. | |
External pressure module | Dual channel serial plug, can connect two digital pressure modules | |
Warm-up time | Full specification performance is achieved after a 10 minute warm-up time. | |
ROHS compliant | Rohs II Directive 2011/65/EU, EN50581:2012 | |
Display rate | 3 readings per second | |
Barometric Accuracy (Built-in barometer) | 55Pa | |
IP protection level | IP67, 1 meter drop test | |
Communication | Isolate USB-TYPEC (slave), Bluetooth BLE | |
User Interface Localization | English, German, French, Italian, Spanish, Portugese, Simplified Chinese, Traditional Chinese, Japanese, Russian, Czech, Slovak | English, Simplified Chinese, Traditional Chinese, Japanese |
Calibration | ISO 17025 accredited calibration with data | |
Warranty | 3 years |
Pressure Specification( ADT226 & ADT226Ex) |
---|
The 161 series Intelligent Digital Pressure Modules are available for gauge, vacuum and absolute pressure from -15 psi to 60,000 psi (-1 bar to 4200 bar). Accuracy from 0.02% FS includes operation over 14°F to 122°F (-10°C to 50°C), one year stability and calibration uncertainty. For detailed specifications, please refer to the pressure modules datasheet. |
Temperature Specification | ||||||||
---|---|---|---|---|---|---|---|---|
Thermocouple Measurement and Source Accuracy | ||||||||
ADT226 | ADT226Ex | |||||||
Type | Standard | Temperature Range (°C) | Accuracy (°C) | Standard | Temperature Range (°C) | Accuracy (°C) | ||
Measure / Source | Measure / Source | |||||||
S | IEC 584 | -50 to 1768 | -50~0 | 0.96 | IEC 584 | -50 to 1768 | -50~100 | 0.96 |
0~100 | 0.69 | 100~1000 | 0.69 | |||||
100~1768 | 0.64 | 1000~1768 | 0.73 | |||||
R | IEC 584 | -50 to 1768 | -50~0 | 1.02 | IEC 584 | -50 to 1768 | -50~0 | 1.03 |
0~200 | 0.71 | 0~200 | 0.71 | |||||
200~1768 | 0.56 | 200~1768 | 0.65 | |||||
B | IEC 584 | 0 to 1820 | 200~300 | 1.89 | IEC 584 | 0 to 1820 | 200~300 | 1.9 |
300~500 | 1.25 | 300~500 | 1.26 | |||||
500~800 | 0.78 | 500~800 | 0.79 | |||||
800~1820 | 0.55 | 800~1820 | 0.57 | |||||
K | IEC 584 | -270 to 1372 | -250 to -200 | 0.97 | IEC 584 | -270 to 1372 | -250 to -200 | 1.04 |
-200 to -100 | 0.3 | -200 to -100 | 0.32 | |||||
-100 to 600 | 0.18 | -100 to 600 | 0.21 | |||||
600 to 1372 | 0.35 | 600 to 1372 | 0.43 | |||||
N | IEC 584 | -270 to 1300 | -250 to -200 | 1.5 | IEC 584 | -270 to 1300 | -250 to -200 | 1.58 |
-200 to -100 | 0.44 | -200 to -100 | 0.46 | |||||
-100 to 1300 | 0.3 | -100 to 1300 | 0.37 | |||||
E | IEC 584 | -270 to 1000 | -250~-200 | 0.54 | IEC 584 | -270 to 1000 | -250~-200 | 0.59 |
-200~-100 | 0.2 | -200~-100 | 0.22 | |||||
-100~700 | 0.15 | -100~700 | 0.18 | |||||
700~1000 | 0.2 | 700~1000 | 0.25 | |||||
J | IEC 584 | -210~1200 | -210~-100 | 0.26 | IEC 584 | -210~1200 | -210~-100 | 0.28 |
-100~700 | 0.15 | -100~700 | 0.19 | |||||
700~1200 | 0.25 | 700~1200 | 0.31 | |||||
T | IEC 584 | -270 to 400 | -250~-100 | 0.74 | IEC 584 | -270 to 400 | -250~-100 | 0.79 |
-100~0 | 0.15 | -100~0 | 0.16 | |||||
0~400 | 0.11 | 0~400 | 0.13 | |||||
C | ASTM E988 | 0 to 2315 | 0 to 1000 | 0.35 | ASTM E988 | 0 to 2315 | 0 to 1000 | 0.4 |
1000 to 1800 | 0.62 | 1000 to 1800 | 0.73 | |||||
1800 to 2315 | 1.02 | 1800 to 2315 | 1.22 | |||||
D | ASTM E988 | 0~2315 | 0~100 | 0.39 | ASTM E988 | 0~2315 | 0~100 | 0.39 |
100~1200 | 0.37 | 100~1200 | 0.43 | |||||
1200~2000 | 0.65 | 1200~2000 | 0.77 | |||||
2000~2315 | 1.03 | 2000~2315 | 1.24 | |||||
G | ASTM E1751 | 0 to 2315 | 50~100 | 1.12 | ASTM E1751 | 0 to 2315 | 50~100 | 1.12 |
100~200 | 0.72 | 100~200 | 0.72 | |||||
200~400 | 0.45 | 200~400 | 0.46 | |||||
400~1500 | 0.37 | 400~1500 | 0.43 | |||||
1500~2315 | 0.77 | 1500~2315 | 0.92 | |||||
L | DIN43710 | -200 to 900 | -200 to -100 | 0.15 | DIN43710 | -200 to 900 | -200 to -100 | 0.16 |
-100 to 400 | 0.13 | -100 to 400 | 0.14 | |||||
400 to 900 | 0.17 | 400 to 900 | 0.2 | |||||
U | DIN43710 | -200 to 600 | -200 to 0 | 0.28 | DIN43710 | -200 to 600 | -200 to 0 | 0.29 |
0 to 600 | 0.13 | 0 to 600 | 0.15 | |||||
Note: Internal CJC is ±0.15°C (-10°C to 50°C ambient temperature) | ||||||||
Accuracy with external cold junction only, for internal cold junction add 0.15 ℃(k=2) |
RTD Measurement and Source Accuracy | ||||
---|---|---|---|---|
Measure and Simulate | Temperature Range (°C) | Accuracy (°C) | ||
ADT226 | ADT226Ex | |||
PT10(385) | -200 to 850 | -200~200 | 0.62 | 0.64 |
200~600 | 0.77 | 0.82 | ||
600~850 | 0.88 | 0.95 | ||
PT25(385) | -200 to 850 | -200~200 | 0.29 | 0.31 |
200~600 | 0.4 | 0.44 | ||
600~850 | 0.47 | 0.54 | ||
PT50(3916) | -200 to 850 | -200~200 | 0.18 | 0.2 |
200~600 | 0.27 | 0.32 | ||
600~850 | 0.34 | 0.4 | ||
PT100(385) PT100(391) PT100(3916) PT100(3926) | -200 to 850 | -200~200 | 0.13 | 0.15 |
200~600 | 0.21 | 0.26 | ||
600~850 | 0.27 | 0.34 | ||
PT200(385) | -200 to 850 | -200~200 | 0.34 | 0.12 |
200~300 | 0.37 | 0.4 | ||
300~600 | 0.46 | 0.51 | ||
600~850 | 0.54 | 0.61 | ||
PT400(385) | -200 to 850 | -200~0 | 0.17 | 0.06 |
0~200 | 0.21 | 0.23 | ||
200~600 | 0.3 | 0.35 | ||
600~850 | 0.37 | 0.44 | ||
PT500(385) | -200 to 850 | -200~200 | 0.18 | 0.2 |
200~600 | 0.27 | 0.32 | ||
600~850 | 0.34 | 0.4 | ||
PT1000(385) | -200 to 850 | -200~200 | 0.13 | 0.15 |
200~600 | 0.21 | 0.26 | ||
600~850 | 0.27 | 0.34 | ||
Cu10(427) | -200~260 | -200~260 | 0.59 | 0.61 |
Cu50(428) | --200~260 | -200~260 | 0.15 | 0.17 |
Cu100(428) | -200~260 | -200~260 | 0.1 | 0.12 |
Ni100(617) Ni100(618) | -60~180 | -60~0 | 0.06 | 0.07 |
0~180 | 0.06 | 0.08 | ||
Ni120(672) | --80~260 | -80~260 | 0.06 | 0.07 |
Ni1000 | -50~150 | -50~150 | 0.08 | 0.09 |
Accessories Included | ||
---|---|---|
Model Number | Description | QTY |
9811-X | 110V/220V external power adapter (Only for ADT226) | 1 pc |
9811Ex-X | 110V/220V external power adapter (Only for ADT226Ex) | 1 pc |
9704 | Chargeable Li-ion battery (Only for ADT226) | 1 pc |
9704Ex | Chargeable Li-ion battery (Only for ADT226Ex) | 1 pc |
9023 | Test leads | 1 set (6 pcs) |
9027 | Right angle test leads kit (Non-Ex models only) | 1 set (2 pcs) |
9060 | Pressure module connection cable | 1 pc |
9052 | USB Cable type A to type C (Non-Ex models only) | 1 pc |
9052Ex | Ex USB Cable type A to type C (For Ex models only) | 1 pc |
9040 | Hanging strap with magnet | 1 pc |
ISO 17025 accredited calibration certificate | 1 pc |
Optional Accessories | |
---|---|
Model Number | Specifications |
ADT161 – XXX | Digital Pressure Modules |
ADT161Ex – XXX | Intrinsically Safe Digital Pressure Modules |
ADT129-X | Differential Pressure Manifold, -15 to 3,000 psi |
9061 | Current output cable (for ADT227 and ADT226 non-Ex models) |
9062 | Connection adapter cable for Fluke style pressure modules to non-explosion-proof Additel readouts |
AM1602-6FT | Class A, PT100/385 Industrial RTD, -40°C to 160°C, 3/16 (4.76 mm) inch x 2 inch (50 mm) with 6 foot (1.8 Meters) cable w/ banana jack connections |
9080 | Cable kit (including TC plug, compensation cable, S, R, K, J, T, E, N) |
9081 | Universal TC easy-press adapter for ADT227 and ADT226 |
9082 | HART 250 ohm resistor adapter for ADT227 and ADT226 |
9704 | Spare chargeable Li-ion battery for multifunction calibrator for ADT226 |
9704Ex | Spare chargeable Li-ion battery for multifunction calibrator for ADT226Ex |
9811-X | 110 V/220 V external power adapter for handheld models |
9811Ex-X | 110 V/220 V external power adapter for Ex handheld models |
9906A | Hard carrying case for handheld instrument with accessories |
9918-SC | Soft carrying case, with space for handheld instrument, test leads, and accessories |
9530-BASIC | Additel/Acal Task management software for multifunction calibrator |
9530-NET | Additel/Acal Automated calibration software with asset management, network version, Includes server installation and 1 user license |
* Additel/Land software can be downloaded for free at www.additel.com.
Software and Firmware | Software and Firmware | ||||
---|---|---|---|---|---|
Name | Version | Upload Date | Size | ||
Additel 226/227 Firmware | 1.0.0.7
Upload Date: 2023-04-28
Size: 57 MB
|
2023-04-28 | 57 MB | ||
Additel 226Ex/227Ex/260Ex/273Ex Firmware Update Tool | 0.33.29.7
Upload Date: 2023-03-31
Size: 26 MB
|
2023-03-31 | 26 MB | ||
Additel 226/227 DD Library for Pressure | 11.3.2022
Upload Date: 2022-11-03
Size: 183 MB
|
2022-11-03 | 183 MB | ||
Additel 226/227 DD Library for Flow and Valves | 11.3.2022
Upload Date: 2022-11-03
Size: 325 MB
|
2022-11-03 | 325 MB | ||
Additel 226/227 DD Library for Temperature | 11.3.2022
Upload Date: 2022-11-03
Size: 90 MB
|
2022-11-03 | 90 MB |
Videos |
---|
Additel 226/227 Multi-functional Documenting Process Calibrator - Full Intro |
Additel 226/227 Multi-Function Documenting Process Calibrator - Mini Intro |
Introduction to the Additel 129 Manifold |